# Parameter Bound scheme ## Static Spectrum fitting * fwhm: broadening parameter * lower bound: 0.5*fwhm_init * upper bound: 2*fwhm_init * peak_factor : parameter to shift or scale peak position * lower bound: 0.5*peak_factor_init * upper bound: 2*peak_factor_init ## Time Delay fitting ## Parameter bound scheme * fwhm: temporal width of x-ray pulse * lower bound: 0.5*fwhm_init * upper bound: 2*fwhm_init * t_0: timezero for each scan * lower bound: t_0 - 2*fwhm_init * upper bound: t_0 + 2*fwhm_init * tau: life_time of each component * if tau < 0.1 * lower bound: tau/2 * upper bound: 1 * if 0.1 < tau < 1 * lower bound: 0.05 * upper bound: 10 * if 1 < tau < 10 * lowe bound: 0.5 * upper bound: 50 * if 10 < tau < 100 * lower bound: 5 * upper bound: 500 * if 100 < tau < 1000 * lower bound: 50 * upper bound: 2000 * if 1000 < tau < 5000 then * lower bound: 500 * upper bound: 10000 * if 5000 < tau < 50000 then * lower bound: 2500 * upper bound: 100000 * if 50000 < tau < 500000 then * lower bound: 25000 * upper bound: 1000000 * if 500000 < tau < 1000000 then * lower bound: 250000 * upper bound: 2000000 * if 1000000 < tau then * lower bound: tau/4 * upper bound: 4*tau